国产精品一区二区视频_欧美亚洲国产成人_欧美5区_午夜精品久久久久久_国产高清在线视频_国产性网

Home | About Biaoqi | News | Product | Contact | 中文

Contact an Biaoqi Applications Scientist

 
Product List
QSpec
OceanOpticsSpectrometer
Light Sources
New Product
* PL-3000 Photoluminescence Spectrometer
* GLIS-3000 GEM Luminous Imaging 
* bluLoop Multi-LED Light Source
* HL-2000 Tungsten Halogen Light 
* LS-1 Tungsten Halogen Light So
* DH-2000 Deuterium Tungsten Halogen&
* Balanced Deuterium Tungsten Halogen
* Miniature Deuterium Tungsten Haloge
* D-2000 Deuterium Light Sources
* High-powered Continuous-wave Xenon 
 
Product

OceanOpticsSpectrometer>> Plasma Spectroscopy>>Laser Assisted Microwave Plasma Spectroscopy  

LAMPS (Laser Assisted Microwave Plasma Spectroscopy), developed in conjunction with Envimetrics, represents a huge leap forward in LIBS technology.

LAMPS features a specially designed microwave cavity to enhance plasma discharge, thereby increasing sensitivity for most potential analytes. Also enhanced are emission line stability and reproducibility, leading to better quantification results. Applications for a variety of diverse analytes requiring greater sensitivity and less ablative sample imprint are now made possible with LAMPS.


LAMPS vs. LIBS Technology
Current LIBS technology permits qualitative analysis of a solid or liquid sample by ablating a minute portion of it, then analyzing the resulting plasma. LAMPS takes this a step further by employing a special microwave cavity. The plasma is injected into this cavity where it reacts with free electrons, greatly increasing sensitivity and producing better line stability and reproducibility. A lower power 50 mJ laser is used in the LAMPS, resulting in less ablation imprint to the sample and greater sensitivity.

LAMPS Components
Spectrometers -- The key to LIBS and LAMPS measurements is the ability to acquire high resolution spectra over a broad wavelength range of a transient event. This is accomplished by coupling 7 HR2000+ spectrometers into one system. Each spectrometer covers ~100-140 nm typically starting at 200nm for Channel A and ending with 980nm for Channel G.

Systems may be configured to start below 200 nm and with fewer channels for element-specific applications. Optical resolution is ~ 0.1nm FWHM. Pixel resolution is ~ 0.05 nm/pixel. In a 7-channel system, there are 14,336 pixels acquiring synchronous spectra. The detector integration time can be as low as 1 ms, and the maximum data transfer rate to the PC is about 500 spectra (14,336 values) per second over the USB 2.0 port.

Sample Chamber -- Provides critical eye safety by using laser safety shielding and safety interlocks on the door. The sample stage is a manual x, y and z positioner, with internal LED illumination for sample positioning. A fiber bundle, inserted inside the microwave cavity, is constructed with a special dielectric tip so that no metals are introduced into the cavity.

The next release will feature a redesign of the power supply so that it will be housed inside the sample chamber, weigh less, and will sustain plasmas greater than 2 ms. CE certification is pending the release of this next generation power supply.

Laser -- We provide Quantel's 50 mJ CFR Pulsed Nd:YAG Laser with our LAMPS system. The CFR design is especially rugged as both resonator mirrors are on the same rigid metal plate. The laser is mounted to the sample chamber and aligned to the focusing optics. A 100 mm lens with manual z-axis control permits focusing or allows defocusing of the laser for better plasma uniformity.

Software – OOILIBS operating software provides control of the lasers; has user-programmable delay for the Q switch; acquires, plots and saves spectra; and provides a spectral line library and correlation function for identification of peaks.

Spectra can be exported to Excel. Application-specific libraries of peaks can be loaded. You can zoom into a wavelength range to look for a peak in the library by double-clicking on the line in the table. Or, the correlation routine will match peaks to wavelengths in the library and rank the elements by how many of the emission lines it found. The user can set baseline and peak width filters for the search.

 

Under the Hood
Dimensions:  

LAMPS Sample Chamber

72.5 x 35.3 x 43.9 cm

Spectrometer System

33.4 x 15.0 x 14.0 cm maximum

Weight:

 

LAMPS Sample Chamber

22.7 kg

Spectrometer System

6.4 kg

Wavelength range

200-980 nm (channel dependent)

Optical Resolution

~ 0.1nm FWHM

Pixel resolution

~ 0.05 nm/pixel

Frame rate

2 per second (with microwave on)

Integration time

1-2 ms

Trigger delay

Programmable in software

Trigger jitter

20 ns

Trigger level

+5V TTL

Microwave frequency

2.45 GHz

Microwave power

1 KW @ 2.5 ms

 
版權所有 2007 廣州標旗光電科技發(fā)展股份有限公司 m.wandangyuan.cn
地址:廣州市黃埔區(qū)彩頻路7號701-1房
電話:(020)38319602 38319620 傳真:(020)38319595 ICP備案:粵ICP備2024341827號 粵公網安備44011202002999
主站蜘蛛池模板: 久久综合欧美 | 黄色在线免费观看视频网站 | 精品国产乱码久久久久久牛牛 | 午夜国产精品视频 | 国产精品美女久久久久久久久久久 | 一级毛片免费一级 | 免费在线成人网 | 黄色一级片免费观看 | 欧美日韩精品一区二区三区四区 | 欧美大片免费影院在线观看 | 国产成人精品一区二 | 亚洲精品成人 | 久久人爽| 久久中文字幕在线观看 | 国产婷婷精品av在线 | 亚洲欧洲日韩 | 日本在线视频一区二区 | 久久久精品亚洲 | 日韩欧美天堂 | 国产精品久久久久久久免费大片 | 草久在线观看 | 国产精品久久久久永久免费观看 | 日韩综合网 | 中文字幕一区二区三区四区五区 | 亚洲综合中文字幕在线观看 | 亚洲色图一区二区三区 | 黄色av免费看 | 国产色视频一区 | 精品国产乱码久久久久久密桃99 | 精品一区二区三区在线观看 | 亚洲福利在线观看 | 不卡久久| 中文字幕四虎 | 久久狠狠| 紧缚调教一区二区三区视频 | 亚洲一区二区精品 | 国产精品久久久久久福利一牛影视 | 亚洲精品乱码久久久久久蜜桃不爽 | 日韩三级电影 | 水卜樱一区二区av | 亚洲精品日韩激情在线电影 |