OceanOpticsSpectrometer>> Oxygen Sensors System>>FOXY Sensor Formulation  

FOXY Sensor Formulation


Our Oxygen Sensing Probes with the FOXY Formulation applied are designed for monitoring partial pressure of oxygen in benign gasses and aqueous liquids. Standard FOXY probe tips are covered with a layer of hydrophobic sol-gel material with a ruthenium compound trapped in the sol-gel matrix. When excited by an LED, the ruthenium complex fluoresces. If the excited ruthenium complex then encounters an oxygen molecule, the excess energy quenches the fluorescent signal. The fluorescence intensity or phase shift is measured by an Ocean Optics spectrometer or NeoFox system, and is related to the partial pressure of oxygen.

Choosing a Probe
Once you choose the best Sensor Coating Formulation for your application, you need to select the fiber optic probe onto which the sensor coating is applied. For a list of fiber optic probes, click here.

FOXY Coating Specifications

Specification  
Principle Photoluminescence-quenching using Ru compound. Measures O2 partial pressure.
Sensor mechanism Phase shift due to change in partial pressure of O2
Applications Benign environment, aqueous liquids and vapors
Time-constant (µsec) dynamic range Air: 2.50, N2: 5.00; Low 1.00, High 7.00
Accuracy: (0–20% O2, 0–50ºC) <5% of reading (using polynomial fit to multipoint calibration)
Response time of probe with no overcoat <1 second in gas, 30-45 seconds in liquid
Response time of dissolved oxygen in liquid (with overcoat) 30-45 seconds
Response time of probe with Overcoat of Oxygen Gas (at 1 atmosphere) 30-60 seconds
Dynamic range of Dissolved Oxygen in liquid 0–40.7 ppm; 0–760 mm Hg partial pressure
Dynamic range of Oxygen Gas (at 1 atmosphere) 0–100% (mole percent); 0–760 mm Hg partial pressure
Stability Dissolved Oxygen in liquid Drift<0.01 ppm per hour
Stability Oxygen Gas (at 1 atmosphere) Drift ~0.03% O2 per hour
Resolution of Dissolved Oxygen in liquid 0.02 ppm at room temperature
Resolution of Oxygen Gas (at 1 atmosphere) 0.05% (0.4 mmHg) at room temperature
Lowest detectable limit of Dissolved Oxygen in liquid 0.02 ppm
Lowest detectable limit of oxygen gas (at 1 atmosphere) 0.05% (0.4 mm Hg)
Overcoat available Yes, order FOXY-AF or FOXY-AF-MG
Temperature range -50ºC to +80ºC
Temperature Temperature sensor and software-supported compensation
Temperature recalibration Only when probe is replaced/refurbished
Probe lifetime Reconditioning recommended once per year
pH operating range 1-10 pH
 
版權(quán)所有 2007 廣州標(biāo)旗光電科技發(fā)展股份有限公司 m.wandangyuan.cn
地址:廣州市黃埔區(qū)彩頻路7號701-1房
電話:(020)38319602 38319620 傳真:(020)38319595 ICP備案:粵ICP備2024341827號 粵公網(wǎng)安備44011202002999
主站蜘蛛池模板: 亚洲成人精品视频 | zzzzyyyy精品国产 | 激情婷婷 | 久草中文在线观看 | 精品国产免费人成在线观看 | 精品一区二区三区在线视频 | 亚洲成人福利网 | av在线免费观看网站 | 国产一级毛片一级 | 亚洲黄色高清 | 欧美黄色网页 | 伊人一区二区三区 | 亚洲天堂中文 | 精品国产青草久久久久福利 | 狠狠影院 | 欧美一区二区精品 | 久久国产综合 | 老熟女毛片 | 婷婷综合激情 | 91精品一区二区 | 国产婷婷色一区二区三区 | 免费啪啪av乱一区 | 国产999精品久久久久 | 国产一级片免费观看 | 国内精品久久久久 | 一区二区三区高清视频在线观看 | 久久久亚洲 | 懂色中文一区二区在线播放 | 国产欧美一区二区 | 国产精品久久久久免费a∨ 欧美黄色精品 | 国产亚洲精品美女久久久久久久久久 | 久久久久9999国产精品 | 看av的网址| 日韩一级片| av中文在线 | 成人免费xxxxx在线视频软件 | 成人网av | 成人日韩视频 | 精品国产一区二区国模嫣然 | 亚洲色图在线播放 | 高清国产一区二区三区 |